![]() ![]() Customers who viewed this product bought. Lector Biometrico de Asistencia Por Huella Zkteco Iclock 360. Return HttpResponse("OK", content_type='text/plain')ĭevice do not use any authentification to communicate with server ! I'm pretty sure that's a big security issue. The ZKTeco iClock-580 is a Time & Attendance and access control terminal with incorporated ZK fingerprint sensor and 3’5 TFT display. DESCRIPCIN iClock 700 ID es una innovadora solucin para control de personal y accesos de su empresa con cmara de. Return HttpResponse("OK", type='http', auth="public", csrf=False) Here is an exemple of implementation with Python type='http', auth="public", csrf=False) The software can simultaneously manage access. As a professional access control software, ZKAccess3.5 is designed to manage all ZKTeco’s access control panels and standalone access control terminals. the third part is clock-in if value=0 and clock-out if value=1 It is a creative APP for both Android and IOS platform which allows you to add, search access control devices and open door on your smartphone.The data sent by device on HTTP data buffer looks like 2\t 16:00:20\t1\t15\t\t0\t0\t\t\t43\nĪs you can see you parse this string with '\t' as the separator of informations User logs (clock_in / clock_out) Device request POST /iclock/cdata?SN=XXXXXXXXXX&table=ATTLOG&Stamp=9999 Your server should just parse this data and respond OK to this request something like this one PIN=2\tName=Johny Deep\tPri=0\tPasswd=\tCard=\tGrp=1\tTZ=0000000100000000\tVerify=0\tViceCard=\tStartDatetime=0\tEndDatetime=0\n ![]() With user information on the HTTP buffer. When a user is registered on the device, the device send this request POST /iclock/cdata?SN=XXXXXXXXXX&table=OPERLOG&Stamp=9999 Note that your ZkTeco Device should have ADMS support, so that you will first configure SERVER-IP and PORT on the device (see your official device documentation on ZKTeco website) You can use a tool like Wireshark to scan HTTP requests made by your device and implement same request/response on your own server.įor exemple, the ZKTeco device model MB560-VL send requests like this one GET and if like the BioTime software, your server just send OKĪs response in text/plain, your device will view your server as a "BioTime" The push SDK is just HTTP request made by ZKTeco device to the Bioserver. Here is the solution I had implement and it work properly. I took one month to find that for that PUSH SDK and ADMS, clearly ZKTeco is not open to share that. ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |